Mills, Mark T., Grafton-Clarke, Ciaran ORCID: https://orcid.org/0000-0002-8537-0806, Williams, Gareth, Gosling, Rebecca C., Al Baraikan, Abdulaziz, Kyriacou, Andreas L., Morris, Paul D., Gunn, Julian P., Swoboda, Peter P., Levelt, Eylem, Tsampasian, Vasiliki, van der Geest, Rob J., Swift, Andrew J., Greenwood, John P., Plein, Sven, Vassiliou, Vass ORCID: https://orcid.org/0000-0002-4005-7752 and Garg, Pankaj ORCID: https://orcid.org/0000-0002-5483-169X (2021) Feasibility and validation of trans-valvular flow derived by four-dimensional flow cardiovascular magnetic resonance imaging in patients with atrial fibrillation. Wellcome Open Research, 6.
Preview |
PDF (Published_Version)
- Published Version
Available under License Creative Commons Attribution. Download (5MB) | Preview |
Abstract
Background: Four-dimensional (4D) flow cardiovascular magnetic resonance imaging (MRI) is an emerging technique used for intra-cardiac blood flow assessment. The role of 4D flow cardiovascular MRI in the assessment of trans-valvular flow in patients with atrial fibrillation (AF) has not previously been assessed. The purpose of this study was to assess the feasibility, image quality, and internal validity of 4D flow cardiovascular MRI in the quantification of trans-valvular flow in patients with AF. Methods: Patients with AF and healthy controls in sinus rhythm underwent cardiovascular MRI, including 4D flow studies. Quality assurance checks were done on the raw data and streamlines. Consistency was investigated by trans-valvular flow assessment between the mitral valve (MV) and the aortic valve (AV). Results: Eight patients with AF (88% male, mean age 62±13 years, mean heart rate (HR) 83±16 beats per minute (bpm)) were included and compared with ten healthy controls (70% male, mean age 41±20 years, mean HR 68.5±9 bpm). All scans were of either good quality with minimal blurring artefacts, or excellent quality with no artefacts. No significant bias was observed between the AV and MV stroke volumes in either healthy controls (-4.8, 95% CI -15.64 to 6.04; P=0.34) or in patients with AF (1.64, 95% CI -4.7 to 7.94; P=0.56). A significant correlation was demonstrated between MV and AV stroke volumes in both healthy controls (r=0.87, 95% CI 0.52 to 0.97; P=0.001) and in AF patients (r=0.82, 95% CI 0.26 to 0.97; P=0.01). Conclusions: In patients with AF, 4D flow cardiovascular MRI is feasible with good image quality, allowing for quantification of trans-valvular flow.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | 4d flow cmr,atrial fibrillation,flow quantification,haemodynamics,validation,medicine (miscellaneous),biochemistry, genetics and molecular biology(all) ,/dk/atira/pure/subjectarea/asjc/2700/2701 |
Faculty \ School: | Faculty of Medicine and Health Sciences > Norwich Medical School |
UEA Research Groups: | Faculty of Medicine and Health Sciences > Research Groups > Cardiovascular and Metabolic Health Faculty of Science > Research Groups > Norwich Epidemiology Centre Faculty of Medicine and Health Sciences > Research Groups > Norwich Epidemiology Centre Faculty of Medicine and Health Sciences > Research Centres > Metabolic Health |
Related URLs: | |
Depositing User: | LivePure Connector |
Date Deposited: | 26 Jun 2021 00:09 |
Last Modified: | 25 Sep 2024 15:38 |
URI: | https://ueaeprints.uea.ac.uk/id/eprint/80340 |
DOI: | 10.12688/wellcomeopenres.16655.2 |
Downloads
Downloads per month over past year
Actions (login required)
View Item |