Schäfer, Valentin S., Chrysidis, Stavros, Dejaco, Christian, Duftner, Christina, Iagnocco, Annamaria, Bruyn, George A., Carrara, Greta, D'Agostino, Maria Antonietta, De Miguel, Eugenio, Diamantopoulos, Andreas P., Fredberg, Ulrich, Hartung, Wolfgang, Hocevar, Alojzija, Juche, Aaron, Kermani, Tanaz A., Koster, Matthew J., Lorenzen, Tove, Macchioni, Pierluigi, Milchert, Marcin, Døhn, Uffe Møller, Mukhtyar, Chetan ORCID: https://orcid.org/0000-0002-9771-6667, Ponte, Cristina, Ramiro, Sofia, Scirè, Carlo A., Terslev, Lene, Warrington, Kenneth J., Dasgupta, Bhaskar and Schmidt, Wolfgang A. (2018) Assessing vasculitis in giant cell arteritis by ultrasound: Results of OMERACT patient-based reliability exercises. Journal of Rheumatology, 45 (9). pp. 1289-1295. ISSN 0315-162X
Full text not available from this repository. (Request a copy)Abstract
OBJECTIVE: To test the reliability of Outcome Measures in Rheumatology Clinical Trials (OMERACT) consensus-based ultrasound definitions for normal and vasculitic temporal and axillary arteries in patients with giant cell arteritis (GCA) and in controls. METHODS: A preliminary 1-day meeting and a full 3-day meeting fulfilling OMERACT Ultrasound Group guidelines were held. Temporal and axillary arteries were examined at 2 timepoints by 12 sonographers on 4 patients with GCA and 2 controls. The aim was to test inter- and intrareader reliability for normal findings, halo sign, and compression sign. In both meetings, patients had established GCA. Pathology was more recent in the full meeting, which was preceded by 6 h of training. Scanning time was 15-20 min instead of 10-13 min. RESULTS: In the preliminary exercise, interreader reliabilities were fair to moderate for the overall diagnosis of GCA (Light κ 0.29-0.51), and poor to fair for identifying vasculitis in the respective anatomical segments (Light κ 0.02-0.46). Intrareader reliabilities were moderate (Cohen κ 0.32-0.64). In the main exercise, interreader reliability was good to excellent (Light κ 0.76-0.86) for the overall diagnosis of GCA, and moderate to good (Light κ 0.46-0.71) for identifying vasculitis in the respective anatomical segments. Intrareader reliability was excellent for diagnosis of GCA (Cohen κ 0.91) and good (Cohen κ 0.71-0.80) for the anatomical segments. CONCLUSION: OMERACT-derived definitions of halo and compression signs of temporal and axillary arteries are reliable in recent-onset GCA if experienced sonographers (> 300 examinations) have 15-20 min for a standardized examination with prior training and apply > 15 MHz probes.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | aged,female,diagnostic imaging,humans,male,middle aged,reproducibility of results,sensitivity and specificity,diagnostic imaging,ultrasonography,diagnostic imaging |
Faculty \ School: | Faculty of Medicine and Health Sciences > Norwich Medical School |
Depositing User: | LivePure Connector |
Date Deposited: | 27 Nov 2019 01:59 |
Last Modified: | 07 Oct 2023 01:02 |
URI: | https://ueaeprints.uea.ac.uk/id/eprint/73086 |
DOI: | 10.3899/jrheum.171428 |
Actions (login required)
View Item |