A 24-month follow-up of a custom-made suture-button assembly for syndesmotic injuries of the ankle

Imam, Mohamed A., Matthana, Ahmed, Kim, Ji Wan and Nabil, Mohamed (2017) A 24-month follow-up of a custom-made suture-button assembly for syndesmotic injuries of the ankle. Journal of Foot and Ankle Surgery, 56 (4). pp. 744-747. ISSN 1542-2224

Full text not available from this repository.

Abstract

In the present retrospective analysis, we introduce a custom suture-button fixation device for acute ankle syndesmotic injuries that allows for early weightbearing without another planned operation for hardware removal. We evaluated 87 consecutive ankles in 87 patients (49 males [56.32%] and 38 females [43.68%]). Of the 87 patients, 15 (17.24%) withdrew or were lost to follow-up, leaving 72 patients (82.76%) in the present study. Their mean age was 35.2 (range 17 to 67) years. Nineteen patients (26.39%) presented with a pure syndesmotic disruption, and 53 (73.61%) had associated malleolar fractures. The American Orthopaedic Foot and Ankle Society scale score improved significantly from 31.2 ± 4.2 preoperatively to 88.5 ± 5.3 at an average of 24 months postoperatively (p < .0043). Revision was undertaken because of implant failure in 4 ankles (5.56%). Two revisions (2.78%) were performed in 2 ankles because of early weightbearing in the first 2 weeks after surgery. The third patient (1.39%) underwent revision at 5 weeks postoperatively. This syndesmotic reduction failure was attributed to failure of the threads, which was noted at the second surgery. The fourth patient (1.39%), a 66-year-old male, underwent revision at 5 months postoperatively because of persistent infection. An 18-month postoperative radiograph was available for all patients. The medial clear space had significantly decreased, from 8.2 ± 3.1 mm preoperatively to 3.5 ± 2.2 mm at 18 months postoperatively (p < .0344). Likewise, the tibiofibular clear space had decreased significantly, from a mean of 8.8 ± 3.7 mm preoperatively to a mean of 3.7 ± 2.2 mm at 18 months postoperatively (p < .0322). In conclusion, suture-button fixation described in the present report delivered satisfactory functional outcomes and anatomic reduction at minimum of 18 months after surgery.

Item Type: Article
Faculty \ School: Faculty of Medicine and Health Sciences > Norwich Medical School
Related URLs:
Depositing User: LivePure Connector
Date Deposited: 17 Oct 2019 12:30
Last Modified: 21 Jun 2023 11:31
URI: https://ueaeprints.uea.ac.uk/id/eprint/72648
DOI: 10.1053/j.jfas.2017.02.010