T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis

Alam, Mohammed H., Auger, Dominique, Smith, Gillian C., He, Taigang, Vassiliou, Vassilios ORCID: https://orcid.org/0000-0002-4005-7752, Baksi, A. John, Wage, Rick, Drivas, Peter, Feng, Yanqiu, Firmin, David N. and Pennell, Dudley J. (2015) T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis. Journal of Cardiovascular Magnetic Resonance, 17. ISSN 1097-6647

[thumbnail of Published manuscript]
Preview
PDF (Published manuscript) - Published Version
Available under License Creative Commons Attribution.

Download (3MB) | Preview

Abstract

Background: Myocardial black blood (BB) T2* relaxometry at 1.5T provides robust, reproducible and calibrated non-invasive assessment of cardiac iron burden. In vitro data has shown that like T2*, novel native Modified Look-Locker Inversion recovery (MOLLI) T1 shortens with increasing tissue iron. The relative merits of T1 and T2* are largely unexplored. We compared the established 1.5T BB T2* technique against native T1 values at 1.5T and 3T in iron overload patients and in normal volunteers. Methods: A total of 73 subjects (42 male) were recruited, comprising 20 healthy volunteers (controls) and 53 patients (thalassemia major 22, sickle cell disease 9, hereditary hemochromatosis 9, other iron overload conditions 13). Single mid-ventricular short axis slices were acquired for BB T2* at 1.5T and MOLLI T1 quantification at 1.5T and 3T. Results: In healthy volunteers, median T1 was 1014 ms (full range 939–1059 ms) at 1.5T and modestly increased to 1165ms (full range 1056–1224 ms) at 3T. All patients with significant cardiac iron overload (1.5T T2* values <20 ms) had T1 values <939 ms at 1.5T, and <1056 ms at 3T. Associations between T2* and T1 were found to be moderate with y =377 · x0.282 at 1.5T (R2 = 0.717), and y =406 · x0.294 at 3T (R2 = 0.715). Measures of reproducibility of T1 appeared superior to T2*. Conclusions: T1 mapping at 1.5T and at 3T can identify individuals with significant iron loading as defined by the current gold standard T2* at 1.5T. However, there is significant scatter between results which may reflect measurement error, but it is also possible that T1 interacts with T2*, or is differentially sensitive to aspects of iron chemistry or other biology. Hurdles to clinical implementation of T1 include the lack of calibration against human myocardial iron concentration, no demonstrated relation to cardiac outcomes, and variation in absolute T1 values between scanners, which makes inter-centre comparisons difficult. The relative merits of T1 at 3T versus T2* at 3T require further consideration.

Item Type: Article
Uncontrolled Keywords: cardiac siderosis,3 tesla,t1 mapping,molli t2*,cardiovascular magnetic resonance,sdg 3 - good health and well-being ,/dk/atira/pure/sustainabledevelopmentgoals/good_health_and_well_being
Faculty \ School: Faculty of Medicine and Health Sciences > Norwich Medical School
UEA Research Groups: Faculty of Medicine and Health Sciences > Research Groups > Cardiovascular and Metabolic Health
Faculty of Science > Research Groups > Norwich Epidemiology Centre
Faculty of Medicine and Health Sciences > Research Groups > Norwich Epidemiology Centre
Faculty of Medicine and Health Sciences > Research Centres > Metabolic Health
Related URLs:
Depositing User: Pure Connector
Date Deposited: 22 Jun 2017 05:05
Last Modified: 19 Oct 2023 02:00
URI: https://ueaeprints.uea.ac.uk/id/eprint/63802
DOI: 10.1186/s12968-015-0207-0

Downloads

Downloads per month over past year

Actions (login required)

View Item View Item