Evaluating new HbA1c methods for adoption by the IFCC and NGSP reference networks using international quality targets

Lenters-Westra, Erna and English, Emma ORCID: https://orcid.org/0000-0002-0480-6744 (2017) Evaluating new HbA1c methods for adoption by the IFCC and NGSP reference networks using international quality targets. Clinical Chemistry and Laboratory Medicine, 55 (9). pp. 1426-1434. ISSN 1434-6621

[thumbnail of Accepted manuscript]
Preview
PDF (Accepted manuscript) - Accepted Version
Download (560kB) | Preview

Abstract

Background: As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. Methods: The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Results: Each of the evaluated HbA1c methods had CVs <3% in SI units and <2% in NGSP units at 46 mmol/mol (6.4%) and 72 mmol/mol (8.7%) and passed the NGSP criteria when compared with six secondary reference measurement procedures (SRMPs). Sigma was 8.6 for Abbott Enzymatic, 3.3 for Roche Cobas c513 and 6.9 for Tosoh G11. No clinically significant interference was detected for the common Hb variants for the three methods. Conclusions: All three methods performed well and are suitable for clinical application in the analysis of HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.

Item Type: Article
Uncontrolled Keywords: hba1c,sigma metrics,ifcc,diabetes,method evaluation,sdg 3 - good health and well-being ,/dk/atira/pure/sustainabledevelopmentgoals/good_health_and_well_being
Faculty \ School: Faculty of Medicine and Health Sciences > School of Health Sciences
UEA Research Groups: Faculty of Medicine and Health Sciences > Research Groups > Health Promotion
Depositing User: Pure Connector
Date Deposited: 29 Mar 2017 00:42
Last Modified: 25 Sep 2024 12:40
URI: https://ueaeprints.uea.ac.uk/id/eprint/63101
DOI: 10.1515/cclm-2017-0109

Downloads

Downloads per month over past year

Actions (login required)