Mannan, A. and Smith, T.O. ORCID: https://orcid.org/0000-0003-1673-2954 (2016) Favourable rotational alignment outcomes in PSI knee arthroplasty: A Level 1 systematic review and meta-analysis. The Knee, 23 (2). pp. 186-190. ISSN 0968-0160
Full text not available from this repository. (Request a copy)Abstract
Background: Implant malposition in total knee arthroplasty (TKA) often results in unsatisfactory outcomes. Rotational malalignment leads to impaired patellar tracking, stability and joint biomechanics. Patient-specific instrumentation aims to improve three-dimensional implant positioning while reducing overall costs of instrumentation. Methods: A PRISMA compliant search of all relevant literature between 2000 and 2014 was performed. The primary outcome of interest was deviation from a neutral femoral and tibial axial alignment of patient-specific instrumentation (PSI) vs conventional instrumentation. Femoral rotation was measured with reference to the transepicondylar axis. Tibial rotation was reported with reference to the anterior tibial tuberosity and a “best fit” with the anterior tibial cortex. Results: Six randomised studies met the inclusion criteria reporting on a total of 444 knees. Computed tomography (CT) based PSI systems were used exclusively in three studies, and two further studies in association with magnetic resonance imaging (MRI). MRI was used exclusively in one study. Mean femoral rotation in the conventional group was: − 1.7 to 1.6° (vs − 1.7 to 1° in the PSI group). Meta-analysis demonstrated a significant treatment effect favouring PSI with increased accuracy in “three-degree outliers” with femoral rotation: Z = 2.07, P = 0.04. A single study reported tibial rotational outcomes with no significant difference demonstrated in conventional instrumentation vs PSI. Conclusions: This Level 1 meta-analysis demonstrates favourable femoral rotational alignment outcomes in PSI knee arthroplasty. Only limited data is available for tibial rotational outcomes. Further studies with standardised “gold-standard” measurement criteria are required to clarify tibial rotational outcomes in PSI TKA.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | patient-specific knee,rotation,randomised controlled trial |
Faculty \ School: | Faculty of Medicine and Health Sciences > School of Health Sciences |
UEA Research Groups: | Faculty of Medicine and Health Sciences > Research Groups > Rehabilitation Faculty of Medicine and Health Sciences > Research Groups > Health Promotion Faculty of Science > Research Groups > Norwich Epidemiology Centre Faculty of Medicine and Health Sciences > Research Groups > Norwich Epidemiology Centre Faculty of Medicine and Health Sciences > Research Centres > Population Health |
Depositing User: | Pure Connector |
Date Deposited: | 18 Mar 2016 12:00 |
Last Modified: | 19 Oct 2023 01:38 |
URI: | https://ueaeprints.uea.ac.uk/id/eprint/57580 |
DOI: | 10.1016/j.knee.2015.08.006 |
Actions (login required)
View Item |