Wilson, Andrew M. and Lipworth, Brian J. (2000) Does response evaluation of the therapeutic index for inhaled corticosteroid therapy in asthmatic patients. American Journal of Medicine, 108 (4). pp. 269-275.
Full text not available from this repository. (Request a copy)Abstract
PURPOSE: Inhaled corticosteroids have beneficial effects on pulmonary function and inflammation in patients with asthma, but they also cause systemic adverse effects, such as adrenal suppression. We evaluated the therapeutic index of inhaled corticosteroids in asthmatic patients by comparing their dose–response effects on lung function, surrogate markers of airway inflammation, and tests of adrenal function. SUBJECTS AND METHODS: After a 10-day placebo run-in, we evaluated the effects of 200 μg, 400 μg, and 800 μg of inhaled budesonide, each dose given twice daily sequentially for 3 weeks in 26 patients, aged 35 ± 12 years (mean ± SD), with mild-to-moderate asthma. Measurements were made of bronchial reactivity, exhaled nitric oxide (a marker of airway inflammation), spirometry, serum eosinophilic cationic protein concentration, and 10-hour overnight urinary cortisol excretion. Plasma cortisol levels were measured at 8 am and after stimulation with human corticotropin releasing factor. RESULTS: For measurements of pulmonary function and exhaled nitric oxide, there was a plateau in the mean response to budesonide between 400 μg (low dose) and 800 μg (medium dose) per day, whereas for eosinophilic cationic protein and bronchial challenge, maximal benefits occurred between 800 and 1,600 μg (high dose) per day. Effects on plasma cortisol levels showed maximal suppression at 1,600 μg of budesonide per day. The proportion of patients with an optimal therapeutic index, in terms of a good airway response (fourfold decrease in bronchial hyperreactivity) and minimal systemic response (overnight urinary cortisol greater than 20 nmol), was similar at low-dose (46%) and at high-dose (52%) budesonide. The proportion of patients with a suboptimal therapeutic index, a good airway response with a marked systemic response (overnight urinary cortisol greater than 20 nmol), increased from 4% at low dose to 38% at high dose. CONCLUSIONS: In patients with mild-to-moderate atopic asthma, there were dose-related effects of budesonide on surrogate markers of inflammation (bronchial hyperreactivity and serum eosinophilic cationic protein), although higher doses were associated with adrenal suppression and a decrease in the therapeutic index.
Item Type: | Article |
---|---|
Faculty \ School: | Faculty of Medicine and Health Sciences > Norwich Medical School |
UEA Research Groups: | Faculty of Medicine and Health Sciences > Research Groups > Respiratory and Airways Group Faculty of Medicine and Health Sciences > Research Groups > Cardiovascular and Metabolic Health Faculty of Medicine and Health Sciences > Research Centres > Metabolic Health Faculty of Medicine and Health Sciences > Research Groups > Norwich Clinical Trials Unit Faculty of Medicine and Health Sciences > Research Centres > Population Health |
Depositing User: | EPrints Services |
Date Deposited: | 25 Nov 2010 11:12 |
Last Modified: | 21 Jun 2024 11:30 |
URI: | https://ueaeprints.uea.ac.uk/id/eprint/14708 |
DOI: | 10.1016/s0002-9343(99)00435-0 |
Actions (login required)
View Item |