Detrimental immediate- and medium-term clinical effects of right ventricular pacing in patients with myocardial fibrosis

Saunderson, Christopher E. D., Paton, Maria F., Brown, Louise A. E., Gierula, John, Chew, Pei G., Das, Arka, Sengupta, Anshuman, Craven, Thomas P., Chowdhary, Amrit, Koshy, Aaron, White, Hazel, Levelt, Eylem, Dall’Armellina, Erica, Garg, Pankaj ORCID: https://orcid.org/0000-0002-5483-169X, Witte, Klaus K., Greenwood, John P., Plein, Sven and Swoboda, Peter P. (2021) Detrimental immediate- and medium-term clinical effects of right ventricular pacing in patients with myocardial fibrosis. Circulation: Cardiovascular Imaging, 14 (5). pp. 426-435. ISSN 1941-9651

[thumbnail of Published_Version]
Preview
PDF (Published_Version) - Published Version
Available under License Creative Commons Attribution.

Download (753kB) | Preview

Abstract

Background: Long-term right ventricular (RV) pacing leads to heart failure or a decline in left ventricular (LV) function in up to a fifth of patients. We aimed to establish whether patients with focal fibrosis detected on late gadolinium enhancement cardiovascular magnetic resonance (CMR) have deterioration in LV function after RV pacing. Methods: We recruited 84 patients with LV ejection fraction ≥40% into 2 observational CMR studies. Patients (n=34) with a dual-chamber device and preserved atrioventricular conduction underwent CMR in 2 asynchronous pacing modes (atrial asynchronous and dual-chamber asynchronous) to compare intrinsic atrioventricular conduction with forced RV pacing. Patients (n=50) with high-grade atrioventricular block underwent CMR before and 6 months after pacemaker implantation to investigate the medium-term effects of RV pacing. Results: The key findings were (1) initiation of RV pacing in patients with fibrosis, compared with those without, was associated with greater immediate changes in both LV end-systolic volume index (5.3±3.5 versus 2.1±2.4 mL/m2; P<0.01) and LV ejection fraction (-5.7±3.4% versus -3.2±2.6%; P=0.02); (2) medium-term RV pacing in patients with fibrosis, compared with those without, was associated with greater changes in LV end-systolic volume index (8.0±10.4 versus -0.6±7.3 mL/m2; P=0.008) and LV ejection fraction (-12.3±7.9% versus -6.7±6.2%; P=0.012); (3) patients with fibrosis did not experience an improvement in quality of life, biomarkers, or functional class after pacemaker implantation; (4) after 6 months of RV pacing, 10 of 50 (20%) patients developed LV ejection fraction <35% and were eligible for upgrade to cardiac resynchronization according to current guidelines. All 10 patients had fibrosis on their preimplant baseline scan and were identified by >1.1 g of fibrosis with 90% sensitivity and 70% specificity. Conclusions: Fibrosis detected on CMR is associated with immediate- and medium-term deterioration in LV function following RV pacing and could be used to identify those at risk of heart failure before pacemaker implantation.

Item Type: Article
Additional Information: Publisher Copyright: © 2021 The Authors. Circulation: Cardiovascular Imaging is published on behalf of the American Heart Association, Inc.
Uncontrolled Keywords: atrioventricular block,biomarkers,fibrosis,heart failure,heart ventricles,radiology nuclear medicine and imaging,cardiology and cardiovascular medicine ,/dk/atira/pure/subjectarea/asjc/2700/2741
Faculty \ School: Faculty of Medicine and Health Sciences > Norwich Medical School
Faculty of Science > School of Environmental Sciences
UEA Research Groups: Faculty of Medicine and Health Sciences > Research Centres > Metabolic Health
Related URLs:
Depositing User: LivePure Connector
Date Deposited: 13 Nov 2021 01:52
Last Modified: 19 Oct 2023 03:08
URI: https://ueaeprints.uea.ac.uk/id/eprint/82096
DOI: 10.1161/CIRCIMAGING.120.012256

Downloads

Downloads per month over past year

Actions (login required)

View Item View Item