Imaging of the intracranial venous system with a contrast-enhanced volumetric interpolated examination

Wetzel, Stephan G., Law, Meng, Lee, Vivian S., Cha, Soonmee, Johnson, Glyn and Nelson, Kim (2003) Imaging of the intracranial venous system with a contrast-enhanced volumetric interpolated examination. European Radiology, 13 (5). pp. 1010-1018. ISSN 0938-7994

Full text not available from this repository. (Request a copy)

Abstract

A contrast-enhanced interpolated, three-dimensional (3D) gradient-echo MR sequence with asymmetric k-space sampling, which we refer to as volumetric interpolated brain examination (VIBE), was evaluated for its depiction of the normal intracranial venous system and compared with two-dimensional (2D) time-of-flight (TOF) MR venography (MRV). Fifteen subjects underwent contrast-enhanced VIBE imaging (TR/TE 8 ms/4.4 ms, flip angle 18°, acquisition time, 2 min 20 s, voxel size approximately 1.5 mm3) and standard 2D TOF MRV (TR/TE 27 ms/9 ms, flip angle 35°). The presence of 19 venous structures per subject was assessed on maximum intensity projections (MIP) of the whole data set (whole-brain MIP) and on MIP images reconstructed spontaneously from source images (interactive MIP/source images). Results from a consensus reading where all imaging techniques and display modalities were available were taken as the standard of reference for the presence of venous structures. In addition, 10 subjects underwent both unenhanced and enhanced VIBE imaging. The value of subtracted data sets (unenhanced VIBE subtracted from enhanced VIBE) was then evaluated. Overall, VIBE provided a superior visualization of the cerebral veins than 2D TOF MRV (VIBE, sensitivity (reader 1/reader 2): 98%/99%, negative predictive value 64%/71%; TOF sensitivity: 85%/84%, negative predictive value 15%/15%; Wilcoxon signed-rank test VIBE vs TOF, p<0.001 for both readers). The VIBE interactive MIP/source images were superior to whole-brain MIP reconstructions. Image subtraction was not necessary for delineation of venous structures but improved small vein conspicuity. Contrast-enhanced VIBE acquisitions are faster and enable a visualization of the normal intracranial venous system superior to that of 2D TOF MRV.

Item Type: Article
Faculty \ School: Faculty of Medicine and Health Sciences > Norwich Medical School
UEA Research Groups: Faculty of Medicine and Health Sciences > Research Groups > Cancer Studies
Faculty of Medicine and Health Sciences > Research Groups > Norwich Clinical Trials Unit
Depositing User: Pure Connector
Date Deposited: 28 Sep 2015 13:50
Last Modified: 21 Oct 2022 01:15
URI: https://ueaeprints.uea.ac.uk/id/eprint/54433
DOI: 10.1007/s00330-002-1714-6

Actions (login required)

View Item View Item