Ulman, Mateusz, Boczar, Krzysztof, Karkowski, Grzegorz, Holcman, Katarzyna, Dębski, Maciej ORCID: https://orcid.org/0000-0002-3669-3916, Kostkiewicz, Magdalena, Lelakowski, Jacek and Ząbek, Andrzej (2026) Survival of patients with cardiac implantable electronic device infections after transvenous lead extraction. Kardiologia Polska, 84 (2). pp. 231-237. ISSN 0022-9032

[thumbnail of 111009-516425-3-PB]
Preview
PDF (111009-516425-3-PB) - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (332kB) | Preview

Abstract

Background: Cardiac implantable electronic device (CIED) infections, particularly CIED-associated infective endocarditis (CIED-associated IE), are associated with a high 1-year mortality rate of 14%–35%, reduced quality of life, and increased burden on the healthcare system. Aims: In this prospective, single-center, high-volume referral study, we aimed to analyze and compare 3 groups of patients who underwent transvenous lead extraction (TLE): patients with CIED-associated IE, patients with pocket infection (PI), and both. Methods: This study included all consecutive patients with CIEDs who underwent TLE due to device-related infection at a tertiary referral hospital between 2011 and 2023. Patients were divided into 3 groups (CIED-associated IE, PI, and both indications) based on the modified Duke criteria. Results: A total of 253 consecutive patients underwent TLE. Of these, 135 (53%) were treated for PI, 90 (36%) for CIED-associated IE, and 28 (11%) for both indications. Almost all procedures (97%) were completed without complications. Patients with CIED-associated IE had significantly higher mortality than patients in the CIED-associated IE + PI group, and patients in the PI group had the lowest mortality. One-year, 2-year, and 5-year overall survival rates in the CIED-associated IE group were 61%, 49%, and 32%, respectively, compared with 77%, 73%, and 56% in the CIED-associated IE + PI group and 90%, 86%, and 67% in the PI group (P <0.001). Conclusions: Patients with CIED-associated IE had almost 4-fold higher 1-year mortality compared to those with PI. Patients with CIED-associated IE and PI had about 2-fold higher 1-year mortality compared to those with PI.

Item Type: Article
Additional Information: Publisher Copyright: © by the Author(s), 2026.
Uncontrolled Keywords: cardiac implantable electronic devices,cied-associated infective endocarditis,transvenous lead extraction,cardiology and cardiovascular medicine ,/dk/atira/pure/subjectarea/asjc/2700/2705
Faculty \ School: Faculty of Medicine and Health Sciences > Norwich Medical School
Related URLs:
Depositing User: LivePure Connector
Date Deposited: 08 Oct 2026 10:46
Last Modified: 11 Oct 2026 05:42
URI: https://ueaeprints.uea.ac.uk/id/eprint/104755
DOI: 10.33963/v.phj.111009

Downloads

Downloads per month over past year

Actions (login required)

View Item View Item